{"id":7250,"date":"2025-09-15T08:47:36","date_gmt":"2025-09-15T08:47:36","guid":{"rendered":"https:\/\/autoclaveequipment.com\/can-autoclave-kill-hiv-virus\/"},"modified":"2025-12-05T01:05:44","modified_gmt":"2025-12-05T01:05:44","slug":"muze-autoklav-zabit-virus-hiv","status":"publish","type":"post","link":"https:\/\/autoclaveequipment.com\/cs\/muze-autoklav-zabit-virus-hiv\/","title":{"rendered":"M\u016f\u017ee autokl\u00e1v zab\u00edt virus Hiv"},"content":{"rendered":"<p>The product information, we usually get from suppliers, are always centered on the product, the benefits, and specifications. But, what most are lacking are vital information regarding the product\u00a1\u00afs cleaning, <a class=\"smart-interlink\" href=\"https:\/\/autoclaveequipment.com\/autoclave-sterilization\/\" title=\"sterilization\">sterilization<\/a> process, and its sterilization container compatibility. The wrong application of the <a class=\"smart-interlink\" href=\"https:\/\/autoclaveequipment.com\/what-is-an-autoclave-4\/\" title=\"autokl\u00e1v\">autokl\u00e1v<\/a> may cause degradation to the product and loss of customer\u00a1\u00afs trust. Therefore, we have this article that will help you cover all bases and will serve as a guide in selecting a product to be autoclaved.<\/p>\n<p>What Is <a class=\"smart-interlink\" href=\"https:\/\/autoclaveequipment.com\/can-you-autoclave-pbs\/\" title=\"PBS\">PBS<\/a>? <\/p>\n<p>PBS neboli fosf\u00e1tem pufrovan\u00fd fyziologick\u00fd roztok je pufrovac\u00ed roztok b\u011b\u017en\u011b pou\u017e\u00edvan\u00fd v biologick\u00e9m a biochemick\u00e9m v\u00fdzkumu. V n\u011bkter\u00fdch laboratorn\u00edch aplikac\u00edch je tak\u00e9 nezbytn\u00fd pro udr\u017een\u00ed pH a osmotick\u00e9 rovnov\u00e1hy. N\u011bkter\u00e9 z funkc\u00ed PBS jsou mimo jin\u00e9 v bun\u011b\u010dn\u00fdch kultur\u00e1ch, p\u0159i \u010di\u0161t\u011bn\u00ed protein\u016f a imunologick\u00fdch testech. Jak vid\u00edte, PBS hraje kl\u00ed\u010dovou roli v mnoha experiment\u00e1ln\u00edch protokolech. Vzhledem k tomu, \u017ee sterilita je v experiment\u00e1ln\u00edch procesech nezbytn\u00e1, z\u016fst\u00e1v\u00e1 ot\u00e1zkou, jak PBS sterilizovat.<\/p>\n<p>Doch\u00e1z\u00ed p\u0159i autokl\u00e1vov\u00e1n\u00ed PBS k n\u011bjak\u00e9 zm\u011bn\u011b vlastnost\u00ed v\u00fdrobku, existuj\u00ed n\u011bjak\u00e1 omezen\u00ed pro jeho pou\u017eit\u00ed p\u0159i sterilizaci? Na tyto a mnoh\u00e9 dal\u0161\u00ed ot\u00e1zky se dozv\u00edte odpov\u011bdi v tomto \u010dl\u00e1nku o PBS (Phosphate Buffered Saline). Jste distributor, prodejce nebo n\u00e1kup\u010d\u00ed? \u010ct\u011bte d\u00e1le, proto\u017ee v\u00e1m pom\u016f\u017eeme u\u010dinit informovan\u00e9 rozhodnut\u00ed o PBS, kter\u00fd budete nab\u00edzet sv\u00fdm z\u00e1kazn\u00edk\u016fm.<\/p>\n<p>\u00davod <\/p>\n<p>PBS je fyziologick\u00fd roztok pou\u017e\u00edvan\u00fd v biologick\u00e9m v\u00fdzkumu k udr\u017een\u00ed pH a osmotick\u00e9 rovnov\u00e1hy bun\u011bk v laboratorn\u00edm prost\u0159ed\u00ed. Skl\u00e1d\u00e1 se z chloridu sodn\u00e9ho, chloridu draseln\u00e9ho, fosfore\u010dnanu sodn\u00e9ho a fosfore\u010dnanu draseln\u00e9ho, kter\u00e9 jsou sm\u00edch\u00e1ny ve specifick\u00e9m pom\u011bru, aby vytvo\u0159ily izotonick\u00fd roztok. Jak jsme ji\u017e uvedli, PBS lze sterilizovat v autokl\u00e1vu, co\u017e je standardn\u00ed metoda sterilizace, p\u0159i n\u00ed\u017e se pou\u017e\u00edv\u00e1 vysokotlak\u00e1 p\u00e1ra. Je v\u0161ak autokl\u00e1vov\u00e1n\u00ed PBS dobr\u00e1 metoda? Zachov\u00e1 si st\u00e1le svou sterilitu, nebo se autokl\u00e1vov\u00e1n\u00edm znehodnot\u00ed? Odpov\u011bdi na tyto ot\u00e1zky se dozv\u00edte v tomto informativn\u00edm \u010dl\u00e1nku o fosf\u00e1tov\u00e9m pufrovan\u00e9m roztoku.<\/p>\n<p>Vlastnosti fosf\u00e1tov\u00e9ho roztoku (PBS) <\/p>\n<p>Slo\u017een\u00ed PBS <\/p>\n<p>PBS se skl\u00e1d\u00e1 z t\u011bchto \u010d\u00e1st\u00ed: <\/p>\n<ol>\n<li>Chlorid sodn\u00fd (NaCl) <\/li>\n<li>Chlorid draseln\u00fd (KCl) <\/li>\n<li>Fosfore\u010dnan sodn\u00fd (Na2HPO4) <\/li>\n<li>Fosfore\u010dnan draseln\u00fd (KH2PO4)<\/li>\n<\/ol>\n<p>Kl\u00ed\u010dov\u00e9 charakteristiky PBS <\/p>\n<ol>\n<li>\n<p>Stabilita pH: PBS m\u00e1 pH v rozmez\u00ed p\u0159ibli\u017en\u011b 7,2 a\u017e 7,4, kter\u00e9 je pova\u017eov\u00e1no za optim\u00e1ln\u00ed pro mnoho biologick\u00fdch proces\u016f. Pufrovac\u00ed kapacita PBS pom\u00e1h\u00e1 udr\u017eet toto pH i po p\u0159id\u00e1n\u00ed mal\u00e9ho mno\u017estv\u00ed kyselin nebo z\u00e1sad.<\/p>\n<\/li>\n<li>\n<p>Izotoni\u010dnost: PBS je izotonick\u00fd, co\u017e znamen\u00e1, \u017ee m\u00e1 stejn\u00fd osmotick\u00fd tlak jako bu\u0148ky, v nich\u017e se pou\u017e\u00edv\u00e1. Tato vlastnost je rozhoduj\u00edc\u00ed pro zachov\u00e1n\u00ed struktur\u00e1ln\u00ed integrity bun\u011bk b\u011bhem experiment\u016f.<\/p>\n<\/li>\n<li>\n<p>Biokompatibilita: PBS je pro bu\u0148ky netoxick\u00fd, a proto je biokompatibiln\u00ed. To z n\u011bj \u010din\u00ed ide\u00e1ln\u00ed m\u00e9dium pro biologick\u00e9 experimenty.<\/p>\n<\/li>\n<li>\n<p>V\u0161estrannost: PBS lze pou\u017e\u00edt v \u0161irok\u00e9 \u0161k\u00e1le aplikac\u00ed, jako je prom\u00fdv\u00e1n\u00ed bun\u011bk, \u0159ed\u011bn\u00ed protil\u00e1tek a p\u0159\u00edprava vzork\u016f k anal\u00fdze.<\/p>\n<\/li>\n<\/ol>\n<p>Proces autokl\u00e1vov\u00e1n\u00ed <\/p>\n<p>Co je autokl\u00e1vov\u00e1n\u00ed? <\/p>\n<p>Autokl\u00e1vov\u00e1n\u00ed je metoda sterilizace, p\u0159i n\u00ed\u017e se k usmrcen\u00ed mikroorganism\u016f, jako jsou bakterie, viry a spory, pou\u017e\u00edv\u00e1 vysokotlak\u00e1 p\u00e1ra. Je to preferovan\u00e1 metoda sterilizace v mnoha pr\u016fmyslov\u00fdch odv\u011btv\u00edch, proto\u017ee je \u00fa\u010dinn\u00e1, rychl\u00e1 a \u0161etrn\u00e1 k \u017eivotn\u00edmu prost\u0159ed\u00ed. Mezi hlavn\u00ed sou\u010d\u00e1sti autokl\u00e1vu pat\u0159\u00ed: <\/p>\n<ol>\n<li>\n<p>Komora: V t\u00e9to komo\u0159e jsou um\u00edst\u011bny p\u0159edm\u011bty ur\u010den\u00e9 ke sterilizaci.<\/p>\n<\/li>\n<li>\n<p>Topn\u00e9 t\u011bleso: Je to sou\u010d\u00e1stka, kter\u00e1 oh\u0159evem vody vyr\u00e1b\u00ed p\u00e1ru. P\u00e1ra se pak pou\u017e\u00edv\u00e1 ke sterilizaci p\u0159edm\u011bt\u016f v komo\u0159e.<\/p>\n<\/li>\n<li>\n<p>Syst\u00e9m \u0159\u00edzen\u00ed tlaku: Jedn\u00e1 se o syst\u00e9m, kter\u00fd udr\u017euje po\u017eadovan\u00fd tlak v komo\u0159e pro dosa\u017een\u00ed po\u017eadovan\u00e9 teploty.<\/p>\n<\/li>\n<li>\n<p>Syst\u00e9m \u0159\u00edzen\u00ed teploty: Jedn\u00e1 se o syst\u00e9m, kter\u00fd monitoruje a reguluje teplotu b\u011bhem steriliza\u010dn\u00edho cyklu.<\/p>\n<\/li>\n<\/ol>\n<p>Jak funguje autokl\u00e1vov\u00e1n\u00ed? <\/p>\n<p>Proces autokl\u00e1vov\u00e1n\u00ed prob\u00edh\u00e1 ve t\u0159ech hlavn\u00edch f\u00e1z\u00edch:<\/p>\n<ol>\n<li>\n<p>F\u00e1ze vyt\u00e1p\u011bn\u00ed: V t\u00e9to f\u00e1zi se voda zah\u0159\u00edv\u00e1, aby se vytvo\u0159ila p\u00e1ra, kter\u00e1 napln\u00ed steriliza\u010dn\u00ed komoru. P\u00e1ra mus\u00ed b\u00fdt nasycen\u00e1, aby bylo zaji\u0161t\u011bno dosa\u017een\u00ed \u00fa\u010dinn\u00e9 sterilizace.<\/p>\n<\/li>\n<li>\n<p>F\u00e1ze sterilizace: Jakmile je dosa\u017eeno po\u017eadovan\u00e9 teploty (obvykle 121 nebo 134 \u00b0C) a tlaku (asi 15-30 psi), za\u010d\u00edn\u00e1 f\u00e1ze sterilizace. Tato f\u00e1ze trv\u00e1 po stanovenou dobu, obvykle 15 a\u017e 30 minut v z\u00e1vislosti na n\u00e1plni.<\/p>\n<\/li>\n<li>\n<p>F\u00e1ze chlazen\u00ed: Po uplynut\u00ed doby sterilizace se tlak postupn\u011b uvol\u0148uje a p\u0159edm\u011bty se ochlazuj\u00ed. Tato f\u00e1ze je nezbytn\u00e1, aby se zabr\u00e1nilo op\u011btovn\u00e9 kontaminaci.<\/p>\n<\/li>\n<\/ol>\n<p>\u00da\u010dinnost proti mikroorganism\u016fm <\/p>\n<p>Autokl\u00e1vov\u00e1n\u00ed \u00fa\u010dinn\u011b ni\u010d\u00ed celou \u0159adu mikroorganism\u016f. Vysok\u00e1 teplota a tlak zaji\u0161\u0165uj\u00ed, \u017ee p\u00e1ra pronik\u00e1 por\u00e9zn\u00edmi materi\u00e1ly a dost\u00e1v\u00e1 se ke v\u0161em povrch\u016fm, \u010d\u00edm\u017e poskytuje komplexn\u00ed steriliza\u010dn\u00ed \u0159e\u0161en\u00ed.<\/p>\n<p>Lze PBS autokl\u00e1vovat? <\/p>\n<p>Autokl\u00e1vovatelnost PBS <\/p>\n<p>Fyziologick\u00fd roztok pufrovan\u00fd fosf\u00e1ty lze autokl\u00e1vovat, ale je t\u0159eba m\u00edt na pam\u011bti n\u011bkolik aspekt\u016f. N\u011bkter\u00e9 z nich zahrnuj\u00ed: <\/p>\n<ol>\n<li>\n<p>Teplotn\u00ed tolerance: Roztoky PBS obvykle sn\u00e1\u0161ej\u00ed autokl\u00e1vov\u00e1n\u00ed p\u0159i teplot\u011b 121 \u00b0C (250 \u00b0F) bez v\u00fdrazn\u00e9 degradace. Je v\u0161ak d\u016fle\u017eit\u00e9 si uv\u011bdomit, \u017ee n\u011bkter\u00e9 slo\u017eky PBS, jako jsou fosf\u00e1tov\u00e9 pufry, mohou b\u00fdt citliv\u00e9 na dlouhodob\u00e9 vystaven\u00ed teplu.<\/p>\n<\/li>\n<li>\n<p>D\u00e9lka expozice: D\u016fle\u017eit\u00e1 je tak\u00e9 doba, po kterou je PBS vystaven vysok\u00fdm teplot\u00e1m b\u011bhem procesu autokl\u00e1vov\u00e1n\u00ed. Standardn\u00ed autokl\u00e1vovac\u00ed cykly obvykle trvaj\u00ed 15 a\u017e 30 minut, co\u017e je pro roztoky PBS obecn\u011b bezpe\u010dn\u00e9.<\/p>\n<\/li>\n<li>\n<p>Koncentrace slo\u017eek: Koncentrace sol\u00ed a pufr\u016f v PBS m\u016f\u017ee ovlivnit jeho stabilitu b\u011bhem autokl\u00e1vov\u00e1n\u00ed. Doporu\u010duje se p\u0159ipravovat PBS ve standardn\u00edch koncentrac\u00edch, aby se minimalizovalo riziko sr\u00e1\u017een\u00ed nebo degradace.<\/p>\n<\/li>\n<\/ol>\n<p>\u00davahy o autokl\u00e1vov\u00e1n\u00ed PBS <\/p>\n<p>I kdy\u017e lze PBS autokl\u00e1vovat, je t\u0159eba vz\u00edt v \u00favahu d\u016fle\u017eit\u00e1 hlediska:<\/p>\n<ol>\n<li>\n<p>Zm\u011bny pH: pH PBS se m\u016f\u017ee b\u011bhem autokl\u00e1vov\u00e1n\u00ed zm\u011bnit v d\u016fsledku rozkladu fosf\u00e1tov\u00fdch pufr\u016f. Je nezbytn\u00e9 zkontrolovat pH po autokl\u00e1vov\u00e1n\u00ed, aby se zajistilo, \u017ee z\u016fstane v po\u017eadovan\u00e9m rozmez\u00ed (7,2 a\u017e 7,4).<\/p>\n<\/li>\n<li>\n<p>Sr\u00e1\u017ekov\u00fd potenci\u00e1l: Vysok\u00e9 teploty mohou zp\u016fsobit sr\u00e1\u017een\u00ed n\u011bkter\u00fdch slo\u017eek v PBS, zejm\u00e9na p\u0159i vy\u0161\u0161\u00edch koncentrac\u00edch. Abyste tomu p\u0159ede\u0161li, je vhodn\u00e9 p\u0159ipravovat roztoky PBS v ni\u017e\u0161\u00edch koncentrac\u00edch, pokud je pl\u00e1nujete autokl\u00e1vovat.<\/p>\n<\/li>\n<li>\n<p>Kontrola po autokl\u00e1vov\u00e1n\u00ed: Po autokl\u00e1vov\u00e1n\u00ed je d\u016fle\u017eit\u00e9 zkontrolovat, zda roztok PBS nevykazuje zn\u00e1mky sr\u00e1\u017een\u00ed nebo zm\u011bny barvy. Pokud zjist\u00edte n\u011bjak\u00e9 probl\u00e9my, roztok by se nem\u011bl pou\u017e\u00edvat pro citliv\u00e9 biologick\u00e9 aplikace.<\/p>\n<\/li>\n<\/ol>\n<p>Osv\u011bd\u010den\u00e9 postupy pro autokl\u00e1vov\u00e1n\u00ed PBS <\/p>\n<p>P\u0159\u00edprava PBS ke sterilizaci <\/p>\n<ol>\n<li>\n<p>P\u0159\u00edprava roztok\u016f: Pro zaji\u0161t\u011bn\u00ed \u010distoty roztok\u016f PBS pou\u017e\u00edvejte vysoce kvalitn\u00ed \u010dinidla. Pro p\u0159\u00edpravu pufru se doporu\u010duje pou\u017e\u00edvat steriln\u00ed vodu.<\/p>\n<\/li>\n<li>\n<p>Spr\u00e1vn\u00e1 filtrace: P\u0159ed autokl\u00e1vov\u00e1n\u00edm je vhodn\u00e9 roztok PBS p\u0159efiltrovat p\u0159es filtr o velikosti 0,22 mikronu. Tento krok pom\u00e1h\u00e1 odstranit ve\u0161ker\u00e9 pevn\u00e9 \u010d\u00e1stice a zaji\u0161\u0165uje, \u017ee roztok neobsahuje kontaminanty.<\/p>\n<\/li>\n<li>\n<p>Pou\u017e\u00edv\u00e1n\u00ed vhodn\u00fdch n\u00e1dob: Pro sterilizaci PBS vyberte n\u00e1doby vhodn\u00e9 pro autokl\u00e1v. Pro autokl\u00e1vov\u00e1n\u00ed se doporu\u010duj\u00ed sklen\u011bn\u00e9 nebo ur\u010dit\u00e9 typy polypropylenov\u00fdch lahv\u00ed.<\/p>\n<\/li>\n<\/ol>\n<p>Obsluha autokl\u00e1vu <\/p>\n<ol>\n<li>\n<p>Dodr\u017eujte pokyny v\u00fdrobce: P\u0159i provozu autokl\u00e1vu je t\u0159eba dodr\u017eovat pokyny v\u00fdrobce. To zahrnuje doporu\u010den\u00e9 nastaven\u00ed teploty, tlaku a \u010dasu.<\/p>\n<\/li>\n<li>\n<p>Pravideln\u00e1 \u00fadr\u017eba: Autokl\u00e1v by m\u011bl b\u00fdt pravideln\u011b udr\u017eov\u00e1n, aby byl zaji\u0161t\u011bn jeho \u00fa\u010dinn\u00fd provoz. Kontrolujte mimo jin\u00e9 t\u011bsn\u011bn\u00ed, ventily a topn\u00e9 t\u011bleso.<\/p>\n<\/li>\n<li>\n<p>Validace a monitorov\u00e1n\u00ed: Pou\u017e\u00edvejte biologick\u00e9 indik\u00e1tory k pravideln\u00e9mu ov\u011b\u0159ov\u00e1n\u00ed \u00fa\u010dinnosti steriliza\u010dn\u00edho cyklu. Sledov\u00e1n\u00ed teploty a tlaku b\u011bhem ka\u017ed\u00e9ho cyklu je nezbytn\u00e9 pro konzistentn\u00ed v\u00fdkonnost.<\/p>\n<\/li>\n<\/ol>\n<p>\u0160kolen\u00ed a vzd\u011bl\u00e1v\u00e1n\u00ed <\/p>\n<p>\u0160kolen\u00ed person\u00e1lu o spr\u00e1vn\u00e9m pou\u017e\u00edv\u00e1n\u00ed autokl\u00e1vu a steriliza\u010dn\u00edch protokolech je nezbytn\u00e9. Tyto znalosti zajist\u00ed, \u017ee pochop\u00ed v\u00fdznam \u00fa\u010dinn\u00e9 sterilizace a budou dodr\u017eovat stanoven\u00e9 postupy.<\/p>\n<p>Z\u00e1v\u011br <\/p>\n<p>Fosf\u00e1tem pufrovan\u00fd fyziologick\u00fd roztok (PBS) je pufrovac\u00ed roztok pou\u017e\u00edvan\u00fd v biologick\u00e9m v\u00fdzkumu, kter\u00fd lze \u00fa\u010dinn\u011b sterilizovat autokl\u00e1vov\u00e1n\u00edm. Jeho vlastnosti, jako je stabilita pH, izotoni\u010dnost a biokompatibilita, z n\u011bj \u010din\u00ed vynikaj\u00edc\u00ed \u0159e\u0161en\u00ed pro r\u016fzn\u00e9 laboratorn\u00ed aplikace. P\u0159i autokl\u00e1vov\u00e1n\u00ed PBS je v\u0161ak d\u016fle\u017eit\u00e9 vz\u00edt v \u00favahu faktory, jako je teplotn\u00ed tolerance, mo\u017en\u00e9 zm\u011bny pH a riziko sr\u00e1\u017een\u00ed.<\/p>\n<p>Jako distributor, prodejce nebo n\u00e1kup\u010d\u00ed je d\u016fle\u017eit\u00e9 zn\u00e1t vlastnosti PBS a jeho kompatibilitu s autokl\u00e1vov\u00e1n\u00edm. Tyto znalosti v\u00e1m pomohou \u010dinit informovan\u00e1 rozhodnut\u00ed p\u0159i v\u00fdb\u011bru metody sterilizace a zajistit kvalitu a bezpe\u010dnost v\u00fdrobk\u016f, kter\u00e9 nab\u00edz\u00edte sv\u00fdm z\u00e1kazn\u00edk\u016fm. Dodr\u017eov\u00e1n\u00edm osv\u011bd\u010den\u00fdch postup\u016f p\u0159i manipulaci s PBS a jeho sterilizaci m\u016f\u017eete vyhov\u011bt pot\u0159eb\u00e1m sv\u00fdch z\u00e1kazn\u00edk\u016f a udr\u017eet si jejich d\u016fv\u011bru.<\/p>\n<p>\u010cASTO KLADEN\u00c9 DOTAZY <\/p>\n<p>Ot\u00e1zka: Lze PBS uchov\u00e1vat v autokl\u00e1vu? <\/p>\n<p>Odpov\u011b\u010f: Ano, fosf\u00e1tem pufrovan\u00fd fyziologick\u00fd roztok (PBS) lze autokl\u00e1vovat. Je v\u0161ak t\u0159eba vz\u00edt v \u00favahu n\u011bkolik faktor\u016f, jako je teplotn\u00ed tolerance a mo\u017en\u00e9 zm\u011bny pH.<\/p>\n<p>Ot\u00e1zka: Jak\u00e1 je maxim\u00e1ln\u00ed teplota pro autokl\u00e1vov\u00e1n\u00ed PBS?<\/p>\n<p>Odpov\u011b\u010f: PBS obecn\u011b sn\u00e1\u0161\u00ed autokl\u00e1vov\u00e1n\u00ed p\u0159i teplot\u011b 121 \u00b0C (250 \u00b0F) bez v\u00fdrazn\u00e9 degradace.<\/p>\n<p>Ot\u00e1zka: Jak dlouho by se m\u011bl PBS uchov\u00e1vat v autokl\u00e1vu? <\/p>\n<p>Odpov\u011b\u010f: Standardn\u00ed autokl\u00e1vovac\u00ed cykly pro PBS obvykle trvaj\u00ed 15 a\u017e 30 minut v z\u00e1vislosti na zat\u00ed\u017een\u00ed a konkr\u00e9tn\u00edch doporu\u010den\u00edch v\u00fdrobce.<\/p>\n<p>Ot\u00e1zka: M\u016f\u017ee se b\u011bhem autokl\u00e1vov\u00e1n\u00ed zm\u011bnit pH PBS?<\/p>\n<p>Odpov\u011b\u010f: Ano, pH PBS se m\u016f\u017ee b\u011bhem autokl\u00e1vov\u00e1n\u00ed zm\u011bnit v d\u016fsledku rozkladu fosf\u00e1tov\u00fdch pufr\u016f. Je nezbytn\u00e9 zkontrolovat pH po autokl\u00e1vov\u00e1n\u00ed, aby se zajistilo, \u017ee z\u016fstane v po\u017eadovan\u00e9m rozmez\u00ed.<\/p>\n<p>Ot\u00e1zka: Co m\u00e1m d\u011blat, pokud PBS po autokl\u00e1vov\u00e1n\u00ed vykazuje zn\u00e1mky sr\u00e1\u017een\u00ed?<\/p>\n<p>Odpov\u011b\u010f: Pokud PBS po autokl\u00e1vov\u00e1n\u00ed vykazuje zn\u00e1mky sr\u00e1\u017een\u00ed nebo zm\u011bny barvy, nem\u011bla by b\u00fdt pou\u017eita pro citliv\u00e9 biologick\u00e9 aplikace. P\u0159ed pou\u017eit\u00edm roztok pe\u010dliv\u011b zkontrolujte. <\/p>","protected":false},"excerpt":{"rendered":"<p>M\u016f\u017ee autokl\u00e1v zab\u00edt virus Hiv<\/p>","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[82],"tags":[],"class_list":["post-7250","post","type-post","status-publish","format-standard","hentry","category-autoclave-machine"],"acf":[],"amp_enabled":true,"_links":{"self":[{"href":"https:\/\/autoclaveequipment.com\/cs\/wp-json\/wp\/v2\/posts\/7250","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/autoclaveequipment.com\/cs\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/autoclaveequipment.com\/cs\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/autoclaveequipment.com\/cs\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/autoclaveequipment.com\/cs\/wp-json\/wp\/v2\/comments?post=7250"}],"version-history":[{"count":2,"href":"https:\/\/autoclaveequipment.com\/cs\/wp-json\/wp\/v2\/posts\/7250\/revisions"}],"predecessor-version":[{"id":8291,"href":"https:\/\/autoclaveequipment.com\/cs\/wp-json\/wp\/v2\/posts\/7250\/revisions\/8291"}],"wp:attachment":[{"href":"https:\/\/autoclaveequipment.com\/cs\/wp-json\/wp\/v2\/media?parent=7250"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/autoclaveequipment.com\/cs\/wp-json\/wp\/v2\/categories?post=7250"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/autoclaveequipment.com\/cs\/wp-json\/wp\/v2\/tags?post=7250"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}