1.1 Basic Principles and Operation The sterilization process in vertical dental autoclaves involves high-pressure saturated steam at temperatures ranging from 121°C to 134°C. The vertical design offers several advantages:
Efficient space utilization
Natural steam circulation
Simplified loading and unloading
Reduced footprint in dental clinics
1.2 Key Components
Stainless steel chamber
Digital control system
Safety valve system
Temperature and pressure sensors
Water reservoir
Steam generator
Door sealing mechanism
2.1 Chamber Specifications
Volume options: 18L, 23L, 45L, 60L
Working pressure: 0.14-0.22MPa
Kisaran suhu: 121°C-134°C
Chamber material: Medical-grade 316L stainless steel
2.2 Safety Features
Double temperature controllers
Perlindungan suhu berlebih
Over-pressure protection
Door safety interlocking system
Emergency exhaust valve
2.3 Compliance Standards
ISO 13485 certification
Persyaratan penandaan CE
FDA guidelines compliance
EN 13060 standards for small steam sterilizers
3.1 Sterilization Cycles
Standard B cycle
Quick B cycle
Flash sterilization
Custom cycles for specific requirements
3.2 Cycle Times
Standard B cycle: 30-45 minutes
Quick B cycle: 20-30 minutes
Drying time: 10-20 minutes
3.3 Energy Efficiency
Power consumption: 1.5-2.5 kW/h
Water consumption: 0.5-1L per cycle
Standby power mode
Fitur hemat energi
4.1 Volume Pricing Structure
Minimum order quantities
Tiered pricing benefits
Bulk shipping arrangements
Custom packaging options
4.2 Distribution Support
Technical documentation
Marketing materials
Training resources
After-sales service network
5.1 Installation Requirements
Power supply specifications
Water quality requirements
Ventilation needs
Space considerations
5.2 Maintenance Schedule
Daily checks
Weekly maintenance
Monthly inspections
Annual service requirements
6.1 Testing Protocols
Vacuum leak test
Tes Bowie-Dick
Biological indicators
Chemical indicators
6.2 Documentation
Cycle recording systems
Kemampuan pencatatan data
Printout options
Digital record keeping
7.1 Market Demand Factors
Growing dental practices
Increasing sterilization standards
Regulatory requirements
Technology advancement
7.2 Return on Investment
Operating costs
Biaya pemeliharaan
Lifetime value
Replacement cycles
Medical equipment distribution depends on vertical dental autoclaves as vital investments. Successful distribution partnerships with satisfied end-users depend on understanding technical specifications alongside compliance requirements and maintenance needs. Modern dental practices require these units because they deliver comprehensive features alongside reliable performance.
Q1: What is the warranty period for vertical dental autoclaves? A: Standard warranty periods range from 12 to 24 months, with extended warranty options available.
Q2: What are the power supply requirements? A: Units typically operate on 220V/50Hz or 110V/60Hz, with specific requirements varying by region.
Q3: How often should maintenance be performed? A: Daily basic checks, weekly cleaning, and annual comprehensive maintenance are recommended.
Q4: What is the expected lifespan of a vertical dental autoclave? A: With proper maintenance, units typically last 8-10 years in professional settings.
Q5: Are spare parts readily available? A: Yes, comprehensive spare parts inventory is maintained for all current models.
For detailed product information and wholesale inquiries:
📧 Email: inquiry@shkeling.com
📱 WhatsApp: +86 182 2182 2482
🌐 Website: https://autoclaveequipment.com
Request your comprehensive product catalog and wholesale pricing today. Our professional team is ready to assist with your specific requirements and provide customized solutions for your market needs.
Sterilisasi berfungsi sebagai elemen penting dalam praktik pengendalian infeksi baik di fasilitas kesehatan maupun lingkungan laboratorium. Sterilisasi autoklaf melalui uap terbukti efektif untuk banyak aplikasi tetapi terbukti tidak optimal dalam
Para profesional medis di seluruh dunia mempercayai autoklaf sebagai alat yang penting untuk memastikan keamanan dan kemandulan instrumen medis. Distributor perangkat medis dan spesialis pengadaan perlu memahami prinsip dan manfaat autoklaf
Kemajuan perawatan kesehatan menjadikannya penting untuk menjaga instrumen medis tetap aman dan steril setiap saat. Distributor, dealer, dan profesional pengadaan alat kesehatan harus memahami metode sterilisasi agar dapat beroperasi secara efektif. Metode sterilisasi yang
Sterilisasi alat dan instrumen medis membutuhkan autoklaf karena melindungi keselamatan pasien dan memfasilitasi kepatuhan terhadap standar peraturan. Sistem autoklaf yang paling canggih pun masih mengalami keterbatasan tertentu. Distributor perangkat medis,
Dalam pembuatan perangkat medis, autoklaf berperan sebagai peralatan penting karena memberikan sterilisasi yang konsisten di berbagai instrumen dan bahan. Autoklaf menggunakan uap jenuh bertekanan tinggi untuk membasmi bakteri, virus, jamur, dan
Autoklaf berfungsi sebagai perangkat penting dalam perawatan kesehatan dan lingkungan ilmiah dengan mensterilkan instrumen dan bahan secara konsisten. Distributor peralatan medis bersama dengan dealer dan profesional pengadaan perlu menjaga autoklaf tetap berfungsi