증기 멸균 원리
Operating temperature range: 121°C to 134°C
Pressure levels: 15-30 PSI
Sterilization time: 15-30 minutes
Validation requirements per ISO 17665
Key Applications
Surgical instruments sterilization
Medical device manufacturing
Laboratory equipment processing
Pharmaceutical production
A. Pre-vacuum Autoclaves
Advanced air removal system
Better penetration for complex instruments
Faster cycle times
Ideal for porous materials
B. Gravity Displacement Autoclaves
Traditional technology
Cost-effective solution
기본적인 멸균 요구 사항에 적합
Simple maintenance requirements
C. Steam Pulse Pressure Autoclaves
Hybrid technology
Enhanced efficiency
Reduced cycle times
Superior steam penetration
Temperature Control
Precise temperature monitoring
Multiple temperature sensors
Digital temperature display
Temperature uniformity ±1°C
Pressure Systems
Automated pressure control
Safety valve systems
Digital pressure monitoring
Pressure range: 0-4 bar
챔버 건설
316L stainless steel
이중벽 구조
Jacket steam heating
Superior insulation
국제 표준
ISO 17665-1:2006
EN 285
AAMI ST79
FDA guidelines
Validation Procedures
Installation Qualification (IQ)
Operational Qualification (OQ)
성능 자격(PQ)
Regular revalidation requirements
제어 시스템
PLC-based control
터치 스크린 인터페이스
Data logging capabilities
Remote monitoring options
안전 기능
Door safety interlocks
Emergency stop systems
압력 안전 밸브
Temperature cut-off
Small Capacity
Chamber size: 100-200L
Ideal for clinics
Compact footprint
Quick cycle times
Medium Capacity
Chamber size: 300-600L
Hospital department use
Balanced efficiency
Multiple load options
대용량
Chamber size: 700-1500L
Industrial scale
High throughput
Energy-efficient operation
예방적 유지보수
Daily checks
Weekly cleaning
Monthly inspections
Annual service requirements
문제 해결
Common issues
Quick solutions
Emergency procedures
Service documentation
The medical device industry must choose appropriate autoclave sterilization equipment to achieve success. Your decision-making process should include an assessment of capacity needs along with compliance requirements and technical specifications. Partner with experienced manufacturers for optimal results.
Q1: What is the typical lifespan of an autoclave? A: With proper maintenance, industrial autoclaves typically last 15-20 years.
Q2: How often should validation be performed? A: Complete validation should be done annually, with periodic testing quarterly.
Q3: What are the energy requirements? A: Power requirements vary from 380V-440V, three-phase, depending on capacity.
Q4: How long does a typical sterilization cycle take? A: Standard cycles range from 45-60 minutes, including drying time.
Q5: What maintenance is required? A: Daily checks, weekly cleaning, and annual professional servicing are recommended.
For expert consultation on autoclave sterilization equipment, contact our specialists:
이메일: inquiry@shkeling.com WhatsApp: +86 182 2182 2482 웹사이트: https://autoclaveequipment.com/
Our team of experts is ready to assist you in selecting the perfect autoclave solution for your specific needs. Contact us today for professional guidance and competitive quotes.
오토클레이브 공정은 의료, 실험실 및 연구 시설에서 효과적인 멸균을 통해 유리 제품과 기구를 보호하기 위해 사용하는 필수 멸균 방식입니다. 고압 증기는 이 과정에서 병원균을 제거합니다.
오토클레이브 공정은 의료, 실험실 및 연구 시설에서 효과적인 멸균을 통해 유리 제품과 기구를 보호하기 위해 사용하는 필수 멸균 방식입니다. 고압 증기는 이 과정에서 병원균을 제거합니다.