{"id":3152,"date":"2025-04-14T05:32:16","date_gmt":"2025-04-14T05:32:16","guid":{"rendered":"https:\/\/autoclaveequipment.com\/?p=3152"},"modified":"2025-12-05T02:28:55","modified_gmt":"2025-12-05T02:28:55","slug":"how-long-do-instruments-stay-sterile-after-autoclaving","status":"publish","type":"post","link":"https:\/\/autoclaveequipment.com\/vi\/how-long-do-instruments-stay-sterile-after-autoclaving\/","title":{"rendered":"How Long Do Instruments Stay Sterile After Autoclaving?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"3152\" class=\"elementor elementor-3152\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-51db60af e-flex e-con-boxed e-con e-parent\" data-id=\"51db60af\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-55d8216f elementor-widget elementor-widget-theme-post-title elementor-page-title elementor-widget-heading\" data-id=\"55d8216f\" data-element_type=\"widget\" data-widget_type=\"theme-post-title.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">How Long Do Instruments Stay Sterile After Autoclaving?<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-292c9340 e-flex e-con-boxed e-con e-parent\" data-id=\"292c9340\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t<div class=\"elementor-element elementor-element-324ae5e7 e-con-full e-flex e-con e-child\" data-id=\"324ae5e7\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-5650cd21 elementor-align-left elementor-widget elementor-widget-post-info\" data-id=\"5650cd21\" data-element_type=\"widget\" data-widget_type=\"post-info.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-inline-items elementor-icon-list-items elementor-post-info\">\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-repeater-item-f7bd4a7 elementor-inline-item\" itemprop=\"author\">\n\t\t\t\t\t\t<a href=\"https:\/\/autoclaveequipment.com\/vi\/author\/autoclave\/\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text elementor-post-info__item elementor-post-info__item--type-author\">\n\t\t\t\t\t\t\t\t\t\tm\u00e1y ti\u1ec7t tr\u00f9ng\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t<\/li>\n\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-60f6729c elementor-widget elementor-widget-theme-post-excerpt\" data-id=\"60f6729c\" data-element_type=\"widget\" data-widget_type=\"theme-post-excerpt.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\tMedical and industrial professionals recognize autoclaving as the top sterilization method across multiple fields. This sterilization process employs high-pressure steam to eradicate microorganisms which makes instruments ready for safe use.\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54804bba elementor-widget elementor-widget-theme-post-featured-image elementor-widget-image\" data-id=\"54804bba\" data-element_type=\"widget\" data-widget_type=\"theme-post-featured-image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<a href=\"\/autoclave-products\" target=\"_blank\">\n\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/autoclaveequipment.com\/wp-content\/uploads\/2025\/03\/Keling-Medical-Autoclave-032.png\" class=\"attachment-full size-full wp-image-2278 not-transparent\" alt=\"Keling-Medical-Autoclave-032\" srcset=\"https:\/\/autoclaveequipment.com\/wp-content\/uploads\/2025\/03\/Keling-Medical-Autoclave-032.png 800w, https:\/\/autoclaveequipment.com\/wp-content\/smush-webp\/2025\/03\/Keling-Medical-Autoclave-032-300x300.png.webp 300w, https:\/\/autoclaveequipment.com\/wp-content\/smush-webp\/2025\/03\/Keling-Medical-Autoclave-032-150x150.png.webp 150w, https:\/\/autoclaveequipment.com\/wp-content\/smush-webp\/2025\/03\/Keling-Medical-Autoclave-032-768x768.png.webp 768w, https:\/\/autoclaveequipment.com\/wp-content\/smush-webp\/2025\/03\/Keling-Medical-Autoclave-032-12x12.png.webp 12w\" sizes=\"(max-width: 800px) 100vw, 800px\" data-has-transparency=\"false\" data-dominant-color=\"94a3aa\" style=\"--dominant-color: #94a3aa\" \/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ff89a41 elementor-widget elementor-widget-text-editor\" data-id=\"ff89a41\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"md-end-block md-p md-focus\"><span class=\"md-plain md-expand\">After autoclaving instruments how long do they remain free from contamination? Several elements like packaging type and how instruments are stored and handled determine the duration of their sterility.<\/span><\/p><p class=\"md-end-block md-p\"><span class=\"md-plain\">Our article examines both the autoclaving procedure and the elements that determine how long items remain sterile along with established methods for preserving sterility. Medical device distributors, dealers, and purchasers must understand these principles to maintain compliance and provide sterile instruments to end users.<\/span><\/p><div class=\"md-hr md-end-block\" tabindex=\"-1\"><hr \/><\/div><h2 class=\"md-end-block md-heading\"><span class=\"md-plain\">The Autoclaving Process <\/span><\/h2><h3 class=\"md-end-block md-heading\"><span class=\"md-plain\">How Do Autoclaves Work? <\/span><\/h3><p class=\"md-end-block md-p\"><span class=\"md-plain\">Through high-pressure steam at temperatures between 121\u00b0C and 134\u00b0C (250\u00b0F to 273\u00b0F), autoclaves effectively sterilize medical instruments. The simultaneous application of heat, pressure, and time eliminates every type of microbial organism including bacteria, viruses, fungi, and spores.<\/span><\/p><p class=\"md-end-block md-p\"><span class=\"md-plain\">The autoclaving process follows these standard steps:<\/span><\/p><ol class=\"ol-list\" start=\"\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Preparation<\/span><\/strong><\/span><span class=\"md-plain\">: Once cleaned, instruments go into sterilization pouches or wraps before autoclaving.<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Loading<\/span><\/strong><\/span><span class=\"md-plain\">: The autoclave receives items which are positioned to maintain adequate space for steam to circulate properly.<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Sterilization Cycle<\/span><\/strong><\/span><span class=\"md-plain\">: The autoclave generates steam by heating water which remains pressurized throughout a designated time period like 15 to 30 minutes.<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Drying<\/span><\/strong><\/span><span class=\"md-plain\">: The autoclave eliminates moisture post-sterilization to prevent any contamination from occurring.<\/span><\/p><\/li><\/ol><h3 class=\"md-end-block md-heading\"><span class=\"md-plain\">Types of Materials That Can Be Autoclaved <\/span><\/h3><p class=\"md-end-block md-p\"><span class=\"md-plain\">Autoclaving works well for multiple kinds of materials like:<\/span><\/p><ul class=\"ul-list\" data-mark=\"-\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Surgical instruments made of stainless steel. <\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Glassware, such as beakers and syringes. <\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Some plastic materials remain stable at high temperatures during sterilization.<\/span><\/p><\/li><\/ul><p class=\"md-end-block md-p\"><span class=\"md-plain\">Materials including heat-sensitive plastics and electronic devices need sterilization methods other than autoclaving such as ethylene oxide or hydrogen peroxide gas plasma.<\/span><\/p><div class=\"md-hr md-end-block\" tabindex=\"-1\"><hr \/><\/div><h2 class=\"md-end-block md-heading\"><span class=\"md-plain\">Sterility Duration After Autoclaving <\/span><\/h2><h3 class=\"md-end-block md-heading\"><span class=\"md-plain\">Key Factors Affecting Sterility <\/span><\/h3><p class=\"md-end-block md-p\"><span class=\"md-plain\">Multiple factors determine the period during which autoclaved instruments maintain sterility.<\/span><\/p><ol class=\"ol-list\" start=\"\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Packaging Integrity:<\/span><\/strong><\/span><\/p><\/li><\/ol><ul class=\"ul-list\" data-mark=\"-\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Sterilization wraps along with pouches and rigid containers need to stay intact and unharmed to maintain sterility.<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Any tears or punctures in packaging or improper sealing can lead to sterility loss.<\/span><\/p><\/li><\/ul><ol class=\"ol-list\" start=\"2\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Storage Environment:<\/span><\/strong><\/span><\/p><\/li><\/ol><ul class=\"ul-list\" data-mark=\"-\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Sterile instruments need to be kept in an environment that remains dry and clean while maintaining a controlled temperature.<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Contaminant exposure or high humidity levels can reduce the time instruments remain sterile.<\/span><\/p><\/li><\/ul><ol class=\"ol-list\" start=\"3\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Handling Practices:<\/span><\/strong><\/span><\/p><\/li><\/ol><ul class=\"ul-list\" data-mark=\"-\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Sterile instruments become contaminated when healthcare professionals handle them without proper protective gloves.<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">You must handle instruments only with sanitized gloves or sterilized instruments handling tools.<\/span><\/p><\/li><\/ul><h3 class=\"md-end-block md-heading\"><span class=\"md-plain\">Typical Sterility Durations <\/span><\/h3><p class=\"md-end-block md-p\"><span class=\"md-plain\">The length of time autoclaved instruments stay sterile depends on how they are packaged and stored.<\/span><\/p><ul class=\"ul-list\" data-mark=\"-\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Sterilization Pouches:<\/span><\/strong><\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Proper storage conditions allow instruments to maintain sterility for a maximum of 6 months.<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Sterile Wraps (Double-Layered):<\/span><\/strong><\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">The sterility of instruments wrapped in double layers can last up to 1 year when stored under perfect conditions.<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Rigid Containers:<\/span><\/strong><\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Rigid containers usually offer the longest sterility time frame which can extend beyond one year.<\/span><\/p><\/li><\/ul><p class=\"md-end-block md-p\"><span class=\"md-plain\">Users should understand these timeframes serve as basic standards. Adhere to both the packaging manufacturer&#8217;s guidelines and industry best practices for sterilization.<\/span><\/p><div class=\"md-hr md-end-block\" tabindex=\"-1\"><hr \/><\/div><h2 class=\"md-end-block md-heading\"><span class=\"md-plain\">Best Practices for Maintaining Sterility <\/span><\/h2><h3 class=\"md-end-block md-heading\"><span class=\"md-plain\">Proper Packaging Techniques <\/span><\/h3><ol class=\"ol-list\" start=\"\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Use High-Quality Materials:<\/span><\/strong><\/span><\/p><\/li><\/ol><ul class=\"ul-list\" data-mark=\"-\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Select sterilization pouches or wraps and containers which are specifically designed for use during autoclaving.<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Choose packaging that works well with the instruments you need to sterilize.<\/span><\/p><\/li><\/ul><ol class=\"ol-list\" start=\"2\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Seal Packaging Correctly:<\/span><\/strong><\/span><\/p><\/li><\/ol><ul class=\"ul-list\" data-mark=\"-\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Heat-sealing machines should be utilized to make pouches airtight.<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Securely fold and tape wraps to maintain their sterility and avoid contamination.<\/span><\/p><\/li><\/ul><ol class=\"ol-list\" start=\"3\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Inspect Packaging:<\/span><\/strong><\/span><\/p><\/li><\/ol><ul class=\"ul-list\" data-mark=\"-\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Inspect packaging for any tears or punctures and verify seals before and after autoclaving.<\/span><\/p><\/li><\/ul><h3 class=\"md-end-block md-heading\"><span class=\"md-plain\">Storage Recommendations <\/span><\/h3><ol class=\"ol-list\" start=\"\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Clean Storage Areas:<\/span><\/strong><\/span><\/p><\/li><\/ol><ul class=\"ul-list\" data-mark=\"-\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Place sterilized instruments in an environment free from dust and cleanliness issues.<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Do not store instruments close to sinks or in areas with a lot of foot traffic.<\/span><\/p><\/li><\/ul><ol class=\"ol-list\" start=\"2\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Temperature and Humidity Control:<\/span><\/strong><\/span><\/p><\/li><\/ol><ul class=\"ul-list\" data-mark=\"-\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Keep the storage area temperature within the range of 15\u00b0C to 30\u00b0C (59\u00b0F to 86\u00b0F).<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">The relative humidity in storage areas should stay within the range of 30% to 60%.<\/span><\/p><\/li><\/ul><ol class=\"ol-list\" start=\"3\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Label and Date Items:<\/span><\/strong><\/span><\/p><\/li><\/ol><ul class=\"ul-list\" data-mark=\"-\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Ensure sterilized instruments have the date of autoclaving clearly marked on them.<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Implement a first-in, first-out (FIFO) system to prioritize the usage of older items before newer ones.<\/span><\/p><\/li><\/ul><h3 class=\"md-end-block md-heading\"><span class=\"md-plain\">Handling Protocols <\/span><\/h3><ol class=\"ol-list\" start=\"\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Minimize Handling:<\/span><\/strong><\/span><\/p><\/li><\/ol><ul class=\"ul-list\" data-mark=\"-\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Limit the number of times sterilized instruments are handled to lower the risk of contamination.<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">All items should be handled using sterile gloves or sterile tools.<\/span><\/p><\/li><\/ul><ol class=\"ol-list\" start=\"2\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Train Staff:<\/span><\/strong><\/span><\/p><\/li><\/ol><ul class=\"ul-list\" data-mark=\"-\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">All staff members should receive training on proper handling and storage protocols.<\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-plain\">Regularly review procedures to ensure compliance. <\/span><\/p><\/li><\/ul><div class=\"md-hr md-end-block\" tabindex=\"-1\"><hr \/><\/div><h2 class=\"md-end-block md-heading\"><span class=\"md-plain\">K\u1ebft lu\u1eadn <\/span><\/h2><p class=\"md-end-block md-p\"><span class=\"md-plain\">The autoclaving process successfully sterilizes medical tools yet requires diligent packaging, storage, and handling procedures to maintain sterility afterward. The application of best practices and industry standards helps maintain the sterility of autoclaved instruments throughout their use period.<\/span><\/p><p class=\"md-end-block md-p\"><span class=\"md-plain\">For more specific considerations in veterinary settings, check out our related article: <\/span><span class=\"md-pair-s\"><strong><span class=\"md-meta-i-c  md-link\"><a href=\"https:\/\/autoclaveequipment.com\/how-long-do-instruments-stay-sterile-after-autoclaving-in-veterinary-settings\/\"><span class=\"md-plain\">How Long Do Instruments Stay Sterile After Autoclaving in Veterinary Settings?<\/span><\/a><\/span><\/strong><\/span><\/p><div class=\"md-hr md-end-block\" tabindex=\"-1\"><hr \/><\/div><h2 class=\"md-end-block md-heading\"><span class=\"md-plain\">Frequently Asked Questions (FAQ) <\/span><\/h2><h3 class=\"md-end-block md-heading\"><span class=\"md-plain\">1. How long do instruments stay sterile in sterilization pouches? <\/span><\/h3><p class=\"md-end-block md-p\"><span class=\"md-plain\">Instruments in sterilization pouches typically remain sterile for up to <\/span><span class=\"md-pair-s\"><strong><span class=\"md-plain\">6 months<\/span><\/strong><\/span><span class=\"md-plain\"> if stored in a clean and controlled environment. <\/span><\/p><h3 class=\"md-end-block md-heading\"><span class=\"md-plain\">2. Can I reuse sterilization pouches or wraps? <\/span><\/h3><p class=\"md-end-block md-p\"><span class=\"md-plain\">No, sterilization pouches and wraps are designed for single use. Reusing them can compromise sterility. <\/span><\/p><h3 class=\"md-end-block md-heading\"><span class=\"md-plain\">3. What should I do if the packaging is damaged? <\/span><\/h3><p class=\"md-end-block md-p\"><span class=\"md-plain\">If the packaging is torn, punctured, or otherwise damaged, the instrument should be re-sterilized before use. <\/span><\/p><h3 class=\"md-end-block md-heading\"><span class=\"md-plain\">4. How should I store autoclaved instruments? <\/span><\/h3><p class=\"md-end-block md-p\"><span class=\"md-plain\">Store autoclaved instruments in a clean, dry, and temperature-controlled environment, away from potential contaminants. <\/span><\/p><h3 class=\"md-end-block md-heading\"><span class=\"md-plain\">5. Do rigid containers provide longer sterility durations? <\/span><\/h3><p class=\"md-end-block md-p\"><span class=\"md-plain\">Yes, rigid containers often provide the longest sterility duration, typically up to <\/span><span class=\"md-pair-s\"><strong><span class=\"md-plain\">1 year or more<\/span><\/strong><\/span><span class=\"md-plain\">, due to their durable design. <\/span><\/p><div class=\"md-hr md-end-block\" tabindex=\"-1\"><hr \/><\/div><h2 class=\"md-end-block md-heading\"><span class=\"md-plain\">Li\u00ean h\u1ec7 v\u1edbi ch\u00fang t\u00f4i <\/span><\/h2><p class=\"md-end-block md-p\"><span class=\"md-plain\">If you have any questions or need assistance with sterilization equipment or medical instruments, feel free to contact us: <\/span><\/p><ul class=\"ul-list\" data-mark=\"-\"><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Email:<\/span><\/strong><\/span> <span class=\"md-meta-i-c  md-link\"><a href=\"mailto:inquiry@shkeling.com\"><span class=\"md-plain\">inquiry@shkeling.com<\/span><\/a><\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">WhatsApp:<\/span><\/strong><\/span> <span class=\"md-meta-i-c  md-link\"><a href=\"https:\/\/wa.me\/8618221822482\" target=\"_blank\" rel=\"noopener\"><span class=\"md-plain\">Click to chat<\/span><\/a><\/span><\/p><\/li><li class=\"md-list-item\"><p class=\"md-end-block md-p\"><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Website:<\/span><\/strong><\/span> <span class=\"md-meta-i-c  md-link\"><a href=\"https:\/\/autoclaveequipment.com\/\"><span class=\"md-plain\">https:\/\/autoclaveequipment.com\/<\/span><\/a><\/span><\/p><\/li><\/ul><p class=\"md-end-block md-p md-focus\"><span class=\"md-plain\">At <\/span><span class=\"md-pair-s\"><strong><span class=\"md-plain\">Keling Medical<\/span><\/strong><\/span><span class=\"md-plain md-expand\">, we\u2019re dedicated to providing high-quality sterilization solutions tailored to your needs. Contact us today to learn more!<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bf42230 elementor-widget elementor-widget-wpforms\" data-id=\"bf42230\" data-element_type=\"widget\" data-widget_type=\"wpforms.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<style id=\"wpforms-css-vars-elementor-widget-bf42230\">\n\t\t\t\t.elementor-widget-wpforms.elementor-element-bf42230 {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-render-modern\" id=\"wpforms-786\"><form id=\"wpforms-form-786\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"786\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/vi\/wp-json\/wp\/v2\/posts\/3152\" data-token=\"fff1c8b52dcc7e6485c4217d8dc508c6\" data-token-time=\"1776284126\" data-trp-original-action=\"\/vi\/wp-json\/wp\/v2\/posts\/3152\"><noscript class=\"wpforms-error-noscript\">Vui l\u00f2ng b\u1eadt JavaScript trong tr\u00ecnh duy\u1ec7t c\u1ee7a b\u1ea1n \u0111\u1ec3 ho\u00e0n th\u00e0nh Form n\u00e0y.<\/noscript><div class=\"wpforms-hidden\" id=\"wpforms-error-noscript\">Vui l\u00f2ng b\u1eadt JavaScript trong tr\u00ecnh duy\u1ec7t c\u1ee7a b\u1ea1n \u0111\u1ec3 ho\u00e0n th\u00e0nh Form n\u00e0y.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-786-field_1-container\" class=\"wpforms-field wpforms-field-layout\" data-field-id=\"1\"><div class=\"wpforms-field-layout-rows wpforms-field-large\"><div class=\"wpforms-layout-row\"><div class=\"wpforms-layout-column wpforms-layout-column-50\"><div id=\"wpforms-786-field_2-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-786-field_2\">T\u00ean <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-786-field_2\" class=\"wpforms-field-medium wpforms-field-required\" name=\"wpforms[fields][2]\" aria-errormessage=\"wpforms-786-field_2-error\" required><\/div><\/div><div class=\"wpforms-layout-column wpforms-layout-column-50\"><div id=\"wpforms-786-field_3-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-786-field_3\">Th\u01b0 \u0111i\u1ec7n t\u1eed <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-786-field_3\" class=\"wpforms-field-medium wpforms-field-required\" name=\"wpforms[fields][3]\" spellcheck=\"false\" aria-errormessage=\"wpforms-786-field_3-error\" required><\/div><\/div><\/div><div class=\"wpforms-layout-row\"><div class=\"wpforms-layout-column wpforms-layout-column-50\"><div id=\"wpforms-786-field_4-container\" class=\"wpforms-field wpforms-field-phone\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-786-field_4\">\u0110i\u1ec7n tho\u1ea1i<\/label><input type=\"tel\" id=\"wpforms-786-field_4\" class=\"wpforms-field-medium\" data-rule-int-phone-field=\"true\" name=\"wpforms[fields][4]\" aria-label=\"\u0110i\u1ec7n tho\u1ea1i\" aria-errormessage=\"wpforms-786-field_4-error\" ><\/div><\/div><div class=\"wpforms-layout-column wpforms-layout-column-50\"><div id=\"wpforms-786-field_5-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"5\"><label class=\"wpforms-field-label\" for=\"wpforms-786-field_5\">Y\u00eau c\u1ea7u<\/label><input type=\"text\" id=\"wpforms-786-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" aria-errormessage=\"wpforms-786-field_5-error\" ><\/div><\/div><\/div><\/div><\/div><\/div><!-- .wpforms-field-container --><div class=\"wpforms-recaptcha-container wpforms-is-turnstile\" ><div class=\"g-recaptcha\" data-sitekey=\"0x4AAAAAABBsNIDhAba_II-I\" data-action=\"FormID-786\"><\/div><input type=\"text\" name=\"g-recaptcha-hidden\" class=\"wpforms-recaptcha-hidden\" style=\"position:absolute!important;clip:rect(0,0,0,0)!important;height:1px!important;width:1px!important;border:0!important;overflow:hidden!important;padding:0!important;margin:0!important;\" data-rule-turnstile=\"1\"><\/div><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"786\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/autoclaveequipment.com\/vi\/wp-json\/wp\/v2\/posts\/3152\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-786\" class=\"wpforms-submit\" data-alt-text=\"Sending...\" data-submit-text=\"Send Inquiry\" aria-live=\"assertive\" value=\"wpforms-submit\">G\u1eedi y\u00eau c\u1ea7u<\/button><img decoding=\"async\" src=\"https:\/\/autoclaveequipment.com\/wp-content\/plugins\/wpforms\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"\u0110ang t\u1ea3i\"><\/div><input type=\"hidden\" name=\"trp-form-language\" value=\"vi\"\/><\/form><\/div>  <!-- .wpforms-container -->\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-39ceba41 e-con-full e-flex e-con e-child\" data-id=\"39ceba41\" data-element_type=\"container\">\n\t\t<div class=\"elementor-element elementor-element-328e0cd2 e-con-full e-flex e-con e-child\" data-id=\"328e0cd2\" data-element_type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-539afb7 elementor-widget elementor-widget-heading\" data-id=\"539afb7\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Chia s\u1ebb:<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c2a2421 elementor-icon-list--layout-inline elementor-align-start elementor-mobile-align-center elementor-list-item-link-full_width elementor-widget elementor-widget-icon-list\" data-id=\"4c2a2421\" data-element_type=\"widget\" data-widget_type=\"icon-list.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<ul class=\"elementor-icon-list-items elementor-inline-items\">\n\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-inline-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fab-facebook-f\" viewbox=\"0 0 320 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M279.14 288l14.22-92.66h-88.91v-60.13c0-25.35 12.42-50.06 52.24-50.06h40.42V6.26S260.43 0 225.36 0c-73.22 0-121.08 44.38-121.08 124.72v70.62H22.89V288h81.39v224h100.17V288z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-inline-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fab-twitter\" viewbox=\"0 0 512 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M459.37 151.716c.325 4.548.325 9.097.325 13.645 0 138.72-105.583 298.558-298.558 298.558-59.452 0-114.68-17.219-161.137-47.106 8.447.974 16.568 1.299 25.34 1.299 49.055 0 94.213-16.568 130.274-44.832-46.132-.975-84.792-31.188-98.112-72.772 6.498.974 12.995 1.624 19.818 1.624 9.421 0 18.843-1.3 27.614-3.573-48.081-9.747-84.143-51.98-84.143-102.985v-1.299c13.969 7.797 30.214 12.67 47.431 13.319-28.264-18.843-46.781-51.005-46.781-87.391 0-19.492 5.197-37.36 14.294-52.954 51.655 63.675 129.3 105.258 216.365 109.807-1.624-7.797-2.599-15.918-2.599-24.04 0-57.828 46.782-104.934 104.934-104.934 30.213 0 57.502 12.67 76.67 33.137 23.715-4.548 46.456-13.32 66.599-25.34-7.798 24.366-24.366 44.833-46.132 57.827 21.117-2.273 41.584-8.122 60.426-16.243-14.292 20.791-32.161 39.308-52.628 54.253z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t\t\t<li class=\"elementor-icon-list-item elementor-inline-item\">\n\t\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-icon\">\n\t\t\t\t\t\t\t<svg aria-hidden=\"true\" class=\"e-font-icon-svg e-fab-linkedin-in\" viewbox=\"0 0 448 512\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"><path d=\"M100.28 448H7.4V148.9h92.88zM53.79 108.1C24.09 108.1 0 83.5 0 53.8a53.79 53.79 0 0 1 107.58 0c0 29.7-24.1 54.3-53.79 54.3zM447.9 448h-92.68V302.4c0-34.7-.7-79.2-48.29-79.2-48.29 0-55.69 37.7-55.69 76.7V448h-92.78V148.9h89.08v40.8h1.3c12.4-23.5 42.69-48.3 87.88-48.3 94 0 111.28 61.9 111.28 142.3V448z\"><\/path><\/svg>\t\t\t\t\t\t<\/span>\n\t\t\t\t\t\t\t\t\t\t<span class=\"elementor-icon-list-text\"><\/span>\n\t\t\t\t\t\t\t\t\t<\/li>\n\t\t\t\t\t\t<\/ul>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4a435af3 elementor-widget elementor-widget-heading\" data-id=\"4a435af3\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Xem th\u00eam b\u00e0i vi\u1ebft<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55b230f4 elementor-grid-1 elementor-posts--thumbnail-left elementor-grid-tablet-2 elementor-grid-mobile-1 elementor-widget elementor-widget-posts\" data-id=\"55b230f4\" data-element_type=\"widget\" data-settings=\"{&quot;classic_columns&quot;:&quot;1&quot;,&quot;classic_columns_tablet&quot;:&quot;2&quot;,&quot;classic_columns_mobile&quot;:&quot;1&quot;,&quot;classic_row_gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:35,&quot;sizes&quot;:[]},&quot;classic_row_gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;classic_row_gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"posts.classic\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-posts-container elementor-posts elementor-posts--skin-classic elementor-grid\" role=\"list\">\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-7344 post type-post status-publish format-standard hentry category-autoclave-machine\" role=\"listitem\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/autoclaveequipment.com\/vi\/why-autoclave-pressure-is-15-psi\/\">\n\t\t\t\tT\u1ea1i sao \u00e1p su\u1ea5t trong n\u1ed3i h\u1ea5p l\u00e0 15 psi?\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-7343 post type-post status-publish format-standard hentry category-autoclave-machine\" role=\"listitem\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/autoclaveequipment.com\/vi\/why-autoclave-at-121-c\/\">\n\t\t\t\tT\u1ea1i sao ph\u1ea3i ti\u1ec7t tr\u00f9ng b\u1eb1ng autoclave \u1edf 121\u00b0C?\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-7342 post type-post status-publish format-standard hentry category-autoclave-machine\" role=\"listitem\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/autoclaveequipment.com\/vi\/why-autoclave-is-the-best-method-of-sterilization\/\">\n\t\t\t\tT\u1ea1i sao ti\u1ec7t tr\u00f9ng b\u1eb1ng autoclave l\u00e0 ph\u01b0\u01a1ng ph\u00e1p ti\u1ec7t tr\u00f9ng t\u1ed1t nh\u1ea5t?\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-7341 post type-post status-publish format-standard hentry category-autoclave-machine\" role=\"listitem\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/autoclaveequipment.com\/vi\/why-autoclave-is-used\/\">\n\t\t\t\tT\u1ea1i sao s\u1eed d\u1ee5ng autoclave?\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<\/div>\n\t\t\t\t<\/article>\n\t\t\t\t<\/div>\n\t\t\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-385389b3 e-con-full e-flex e-con e-child\" data-id=\"385389b3\" data-element_type=\"container\" data-settings=\"{&quot;background_background&quot;:&quot;classic&quot;}\">\n\t\t\t\t<div class=\"elementor-element elementor-element-3eaa3ce elementor-widget elementor-widget-heading\" data-id=\"3eaa3ce\" data-element_type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">H\u00e3y g\u1eedi cho ch\u00fang t\u00f4i m\u1ed9t tin nh\u1eafn.<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f622abc elementor-widget elementor-widget-wpforms\" data-id=\"f622abc\" data-element_type=\"widget\" data-widget_type=\"wpforms.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<style id=\"wpforms-css-vars-elementor-widget-f622abc\">\n\t\t\t\t.elementor-widget-wpforms.elementor-element-f622abc {\n\t\t\t\t--wpforms-field-size-input-height: 43px;\n--wpforms-field-size-input-spacing: 15px;\n--wpforms-field-size-font-size: 16px;\n--wpforms-field-size-line-height: 19px;\n--wpforms-field-size-padding-h: 14px;\n--wpforms-field-size-checkbox-size: 16px;\n--wpforms-field-size-sublabel-spacing: 5px;\n--wpforms-field-size-icon-size: 1;\n--wpforms-label-size-font-size: 16px;\n--wpforms-label-size-line-height: 19px;\n--wpforms-label-size-sublabel-font-size: 14px;\n--wpforms-label-size-sublabel-line-height: 17px;\n--wpforms-button-size-font-size: 17px;\n--wpforms-button-size-height: 41px;\n--wpforms-button-size-padding-h: 15px;\n--wpforms-button-size-margin-top: 10px;\n\n\t\t\t}\n\t\t\t<\/style><div class=\"wpforms-container wpforms-container-full wpforms-render-modern\" id=\"wpforms-786\"><form id=\"wpforms-form-786\" class=\"wpforms-validate wpforms-form wpforms-ajax-form\" data-formid=\"786\" method=\"post\" enctype=\"multipart\/form-data\" action=\"\/vi\/wp-json\/wp\/v2\/posts\/3152\" data-token=\"fff1c8b52dcc7e6485c4217d8dc508c6\" data-token-time=\"1776284126\" data-trp-original-action=\"\/vi\/wp-json\/wp\/v2\/posts\/3152\"><noscript class=\"wpforms-error-noscript\">Vui l\u00f2ng b\u1eadt JavaScript trong tr\u00ecnh duy\u1ec7t c\u1ee7a b\u1ea1n \u0111\u1ec3 ho\u00e0n th\u00e0nh Form n\u00e0y.<\/noscript><div class=\"wpforms-hidden\" id=\"wpforms-error-noscript\">Vui l\u00f2ng b\u1eadt JavaScript trong tr\u00ecnh duy\u1ec7t c\u1ee7a b\u1ea1n \u0111\u1ec3 ho\u00e0n th\u00e0nh Form n\u00e0y.<\/div><div class=\"wpforms-field-container\"><div id=\"wpforms-786-field_1-container\" class=\"wpforms-field wpforms-field-layout\" data-field-id=\"1\"><div class=\"wpforms-field-layout-rows wpforms-field-large\"><div class=\"wpforms-layout-row\"><div class=\"wpforms-layout-column wpforms-layout-column-50\"><div id=\"wpforms-786-field_2-container\" class=\"wpforms-field wpforms-field-name\" data-field-id=\"2\"><label class=\"wpforms-field-label\" for=\"wpforms-786-field_2\">T\u00ean <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"text\" id=\"wpforms-786-field_2\" class=\"wpforms-field-medium wpforms-field-required\" name=\"wpforms[fields][2]\" aria-errormessage=\"wpforms-786-field_2-error\" required><\/div><\/div><div class=\"wpforms-layout-column wpforms-layout-column-50\"><div id=\"wpforms-786-field_3-container\" class=\"wpforms-field wpforms-field-email\" data-field-id=\"3\"><label class=\"wpforms-field-label\" for=\"wpforms-786-field_3\">Th\u01b0 \u0111i\u1ec7n t\u1eed <span class=\"wpforms-required-label\" aria-hidden=\"true\">*<\/span><\/label><input type=\"email\" id=\"wpforms-786-field_3\" class=\"wpforms-field-medium wpforms-field-required\" name=\"wpforms[fields][3]\" spellcheck=\"false\" aria-errormessage=\"wpforms-786-field_3-error\" required><\/div><\/div><\/div><div class=\"wpforms-layout-row\"><div class=\"wpforms-layout-column wpforms-layout-column-50\"><div id=\"wpforms-786-field_4-container\" class=\"wpforms-field wpforms-field-phone\" data-field-id=\"4\"><label class=\"wpforms-field-label\" for=\"wpforms-786-field_4\">\u0110i\u1ec7n tho\u1ea1i<\/label><input type=\"tel\" id=\"wpforms-786-field_4\" class=\"wpforms-field-medium\" data-rule-int-phone-field=\"true\" name=\"wpforms[fields][4]\" aria-label=\"\u0110i\u1ec7n tho\u1ea1i\" aria-errormessage=\"wpforms-786-field_4-error\" ><\/div><\/div><div class=\"wpforms-layout-column wpforms-layout-column-50\"><div id=\"wpforms-786-field_5-container\" class=\"wpforms-field wpforms-field-text\" data-field-id=\"5\"><label class=\"wpforms-field-label\" for=\"wpforms-786-field_5\">Y\u00eau c\u1ea7u<\/label><input type=\"text\" id=\"wpforms-786-field_5\" class=\"wpforms-field-medium\" name=\"wpforms[fields][5]\" aria-errormessage=\"wpforms-786-field_5-error\" ><\/div><\/div><\/div><\/div><\/div><\/div><!-- .wpforms-field-container --><div class=\"wpforms-recaptcha-container wpforms-is-turnstile\" ><div class=\"g-recaptcha\" data-sitekey=\"0x4AAAAAABBsNIDhAba_II-I\" data-action=\"FormID-786\"><\/div><input type=\"text\" name=\"g-recaptcha-hidden\" class=\"wpforms-recaptcha-hidden\" style=\"position:absolute!important;clip:rect(0,0,0,0)!important;height:1px!important;width:1px!important;border:0!important;overflow:hidden!important;padding:0!important;margin:0!important;\" data-rule-turnstile=\"1\"><\/div><div class=\"wpforms-submit-container\" ><input type=\"hidden\" name=\"wpforms[id]\" value=\"786\"><input type=\"hidden\" name=\"page_title\" value=\"\"><input type=\"hidden\" name=\"page_url\" value=\"https:\/\/autoclaveequipment.com\/vi\/wp-json\/wp\/v2\/posts\/3152\"><input type=\"hidden\" name=\"url_referer\" value=\"\"><button type=\"submit\" name=\"wpforms[submit]\" id=\"wpforms-submit-786\" class=\"wpforms-submit\" data-alt-text=\"Sending...\" data-submit-text=\"Send Inquiry\" aria-live=\"assertive\" value=\"wpforms-submit\">G\u1eedi y\u00eau c\u1ea7u<\/button><img decoding=\"async\" src=\"https:\/\/autoclaveequipment.com\/wp-content\/plugins\/wpforms\/assets\/images\/submit-spin.svg\" class=\"wpforms-submit-spinner\" style=\"display: none;\" width=\"26\" height=\"26\" alt=\"\u0110ang t\u1ea3i\"><\/div><input type=\"hidden\" name=\"trp-form-language\" value=\"vi\"\/><\/form><\/div>  <!-- .wpforms-container -->\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-f412089 e-flex e-con-boxed e-con e-parent\" data-id=\"f412089\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-ceeb395 elementor-grid-3 elementor-grid-tablet-2 elementor-grid-mobile-1 elementor-posts--thumbnail-top elementor-card-shadow-yes elementor-posts__hover-gradient elementor-widget elementor-widget-posts\" data-id=\"ceeb395\" data-element_type=\"widget\" data-settings=\"{&quot;cards_columns&quot;:&quot;3&quot;,&quot;cards_columns_tablet&quot;:&quot;2&quot;,&quot;cards_columns_mobile&quot;:&quot;1&quot;,&quot;cards_row_gap&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:35,&quot;sizes&quot;:[]},&quot;cards_row_gap_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;cards_row_gap_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"posts.cards\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-posts-container elementor-posts elementor-posts--skin-cards elementor-grid\" role=\"list\">\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-7344 post type-post status-publish format-standard hentry category-autoclave-machine\" role=\"listitem\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/autoclaveequipment.com\/vi\/why-autoclave-pressure-is-15-psi\/\">\n\t\t\t\tT\u1ea1i sao \u00e1p su\u1ea5t trong n\u1ed3i h\u1ea5p l\u00e0 15 psi?\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>T\u1ea1i sao \u00e1p su\u1ea5t trong n\u1ed3i h\u1ea5p l\u00e0 15 psi?<\/p>\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/autoclaveequipment.com\/vi\/why-autoclave-pressure-is-15-psi\/\" aria-label=\"Read more about Why Autoclave Pressure Is 15 Psi\" tabindex=\"-1\">\n\t\t\t\u0110\u1ecdc th\u00eam \u00bb\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-author\">\n\t\t\tm\u00e1y ti\u1ec7t tr\u00f9ng\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-7343 post type-post status-publish format-standard hentry category-autoclave-machine\" role=\"listitem\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/autoclaveequipment.com\/vi\/why-autoclave-at-121-c\/\">\n\t\t\t\tT\u1ea1i sao ph\u1ea3i ti\u1ec7t tr\u00f9ng b\u1eb1ng autoclave \u1edf 121\u00b0C?\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>T\u1ea1i sao ph\u1ea3i ti\u1ec7t tr\u00f9ng b\u1eb1ng autoclave \u1edf 121\u00b0C?<\/p>\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/autoclaveequipment.com\/vi\/why-autoclave-at-121-c\/\" aria-label=\"Read more about Why Autoclave At 121 C\" tabindex=\"-1\">\n\t\t\t\u0110\u1ecdc th\u00eam \u00bb\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-author\">\n\t\t\tm\u00e1y ti\u1ec7t tr\u00f9ng\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-7342 post type-post status-publish format-standard hentry category-autoclave-machine\" role=\"listitem\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/autoclaveequipment.com\/vi\/why-autoclave-is-the-best-method-of-sterilization\/\">\n\t\t\t\tT\u1ea1i sao ti\u1ec7t tr\u00f9ng b\u1eb1ng autoclave l\u00e0 ph\u01b0\u01a1ng ph\u00e1p ti\u1ec7t tr\u00f9ng t\u1ed1t nh\u1ea5t?\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>T\u1ea1i sao ti\u1ec7t tr\u00f9ng b\u1eb1ng autoclave l\u00e0 ph\u01b0\u01a1ng ph\u00e1p ti\u1ec7t tr\u00f9ng t\u1ed1t nh\u1ea5t?<\/p>\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/autoclaveequipment.com\/vi\/why-autoclave-is-the-best-method-of-sterilization\/\" aria-label=\"Read more about Why Autoclave Is The Best Method Of Sterilization\" tabindex=\"-1\">\n\t\t\t\u0110\u1ecdc th\u00eam \u00bb\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-author\">\n\t\t\tm\u00e1y ti\u1ec7t tr\u00f9ng\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-7341 post type-post status-publish format-standard hentry category-autoclave-machine\" role=\"listitem\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/autoclaveequipment.com\/vi\/why-autoclave-is-used\/\">\n\t\t\t\tT\u1ea1i sao s\u1eed d\u1ee5ng autoclave?\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>T\u1ea1i sao s\u1eed d\u1ee5ng autoclave?<\/p>\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/autoclaveequipment.com\/vi\/why-autoclave-is-used\/\" aria-label=\"Read more about Why Autoclave Is Used\" tabindex=\"-1\">\n\t\t\t\u0110\u1ecdc th\u00eam \u00bb\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-author\">\n\t\t\tm\u00e1y ti\u1ec7t tr\u00f9ng\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-7340 post type-post status-publish format-standard hentry category-autoclave-machine\" role=\"listitem\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/autoclaveequipment.com\/vi\/why-autoclave-temperature-is-121\/\">\n\t\t\t\tT\u1ea1i sao nhi\u1ec7t \u0111\u1ed9 c\u1ee7a m\u00e1y ti\u1ec7t tr\u00f9ng l\u00e0 121\u00b0C?\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>T\u1ea1i sao nhi\u1ec7t \u0111\u1ed9 c\u1ee7a m\u00e1y ti\u1ec7t tr\u00f9ng l\u00e0 121\u00b0C?<\/p>\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/autoclaveequipment.com\/vi\/why-autoclave-temperature-is-121\/\" aria-label=\"Read more about Why Autoclave Temperature Is 121\" tabindex=\"-1\">\n\t\t\t\u0110\u1ecdc th\u00eam \u00bb\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-author\">\n\t\t\tm\u00e1y ti\u1ec7t tr\u00f9ng\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<article class=\"elementor-post elementor-grid-item post-7339 post type-post status-publish format-standard hentry category-autoclave-machine\" role=\"listitem\">\n\t\t\t<div class=\"elementor-post__card\">\n\t\t\t\t<div class=\"elementor-post__text\">\n\t\t\t\t<h3 class=\"elementor-post__title\">\n\t\t\t<a href=\"https:\/\/autoclaveequipment.com\/vi\/who-trs-for-autoclave-validation\/\">\n\t\t\t\tAi ch\u1ecbu tr\u00e1ch nhi\u1ec7m v\u1ec1 vi\u1ec7c x\u00e1c nh\u1eadn ti\u1ec7t tr\u00f9ng b\u1eb1ng autoclave?\t\t\t<\/a>\n\t\t<\/h3>\n\t\t\t\t<div class=\"elementor-post__excerpt\">\n\t\t\t<p>Ai ch\u1ecbu tr\u00e1ch nhi\u1ec7m v\u1ec1 vi\u1ec7c x\u00e1c nh\u1eadn ti\u1ec7t tr\u00f9ng b\u1eb1ng autoclave?<\/p>\t\t<\/div>\n\t\t\n\t\t<a class=\"elementor-post__read-more\" href=\"https:\/\/autoclaveequipment.com\/vi\/who-trs-for-autoclave-validation\/\" aria-label=\"Read more about Who Trs For Autoclave Validation\" tabindex=\"-1\">\n\t\t\t\u0110\u1ecdc th\u00eam \u00bb\t\t<\/a>\n\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-post__meta-data\">\n\t\t\t\t\t<span class=\"elementor-post-author\">\n\t\t\tm\u00e1y ti\u1ec7t tr\u00f9ng\t\t<\/span>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/article>\n\t\t\t\t<\/div>\n\t\t\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Medical and industrial professionals recognize autoclaving as the top sterilization method across multiple fields. This sterilization process employs high-pressure steam to eradicate microorganisms which makes instruments ready for safe use.<\/p>","protected":false},"author":1,"featured_media":2278,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"elementor_header_footer","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[26],"tags":[],"class_list":["post-3152","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-autoclave-instructions"],"acf":[],"amp_enabled":false,"_links":{"self":[{"href":"https:\/\/autoclaveequipment.com\/vi\/wp-json\/wp\/v2\/posts\/3152","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/autoclaveequipment.com\/vi\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/autoclaveequipment.com\/vi\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/autoclaveequipment.com\/vi\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/autoclaveequipment.com\/vi\/wp-json\/wp\/v2\/comments?post=3152"}],"version-history":[{"count":5,"href":"https:\/\/autoclaveequipment.com\/vi\/wp-json\/wp\/v2\/posts\/3152\/revisions"}],"predecessor-version":[{"id":8781,"href":"https:\/\/autoclaveequipment.com\/vi\/wp-json\/wp\/v2\/posts\/3152\/revisions\/8781"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/autoclaveequipment.com\/vi\/wp-json\/wp\/v2\/media\/2278"}],"wp:attachment":[{"href":"https:\/\/autoclaveequipment.com\/vi\/wp-json\/wp\/v2\/media?parent=3152"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/autoclaveequipment.com\/vi\/wp-json\/wp\/v2\/categories?post=3152"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/autoclaveequipment.com\/vi\/wp-json\/wp\/v2\/tags?post=3152"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}